Powered Air-Purifying Respirators (PAPR) deliver a continuous flow of filtered air, offering superior comfort and protection for workers in demanding environments. Every certified PAPR in our range meets AS/NZS respiratory protection standards, giving you confidence in performance and compliance
on-site. Ideal for extended wear, PAPRs reduce breathing resistance and fatigue compared to traditional full-face respirators , making them a smart choice for high-exposure tasks like welding, spray painting, and dust-heavy environments. Explore our full range of respiratory protection to find the right fit for your workplace.
Narrow By
45 Products
45 Products
FAQS
A Powered Air Purifying Respirator (PAPR) is a battery-powered respiratory protection system that draws contaminated air through a filter before delivering clean, filtered air to the wearer. The positive airflow helps reduce breathing resistance while providing high levels of respiratory protection.
The TRIDENT® HEXHALE® PAPR has been designed for a wide range of industries, including:
- Mining
- Construction
- Oil & Gas
- Manufacturing
- Agriculture
- Healthcare
- Pharmaceutical Production
- Painting & Coating
- Welding, Grinding & Sanding
- Industrial Maintenance
The system provides comprehensive protection for the:
- Respiratory System
- Eyes
- Face
- Head
Using the approved P3 particle filter, the system delivers filtration efficiency of up to 99.997% against airborne particulates. Different filter options are also available for applications involving gases and vapours.
While PAPRs generally have different fit requirements than tight-fitting disposable respirators, users should always follow their workplace respiratory protection program and local regulations. Proper training, fitting and maintenance are essential for achieving the intended level of protection.
The TRIDENT® HEXHALE® system offers multiple approved filter options, including:
- P3 Particle Filter
- A1 Organic Vapour Filter
- ABEK1 Multi-Gas Filter
- Pre-Filter
- Spark Screen
Battery runtime depends on the airflow setting selected.
- Standard Fast-Charging Battery: Up to 10 Hours
- Extended Fast-Charging Battery: Up to 19 Hours
Runtime will vary depending on airflow speed and operating conditions.
The blower provides three adjustable airflow settings:
- 170 L/min
- 190 L/min
- 210 L/min
Users can select the airflow level that best suits their work environment and comfort.
The TRIDENT® HEXHALE® PAPR continuously monitors:
- Airflow
- Battery Level
- Filter Condition
If performance falls below safe operating levels, the system activates an automatic alarm to alert the wearer.
Yes. The spacious headtop design accommodates many users wearing prescription glasses, and an optional spectacle kit is also available for improved comfort and compatibility.
Yes. The system incorporates a high-impact resistant visor together with an industrial-rated helmet, providing protection for the face and head in demanding work environments.
Yes. Disposable protective visor films are available and can be replaced as required to help extend visor life and maintain visibility.
Yes. Disposable protective visor films are available and can be replaced as required to help extend visor life and maintain visibility.
- Lightweight integrated design
- Adjustable airflow
- Even weight distribution
- Reduced breathing resistance
- Comfortable head suspension
These features help reduce fatigue during long working hours.
Yes. Both the standard and extended batteries are fast charging, helping minimise downtime between shifts.
Yes. The TRIDENT® HEXHALE® PAPR is certified to AS/NZS 1716:2012, providing confidence that it meets Australian and New Zealand respiratory protection standards when used with approved components.
A comprehensive range of accessories is available, including:
- Standard and Extended Batteries
- Backpack
- Protective Visor
- Lens Covers
- Particle Filters
- Gas Filters
- Spark Screens
- Pre-Filters
- Lamp Bracket
- Spectacle Kit
- Carry Bag
- Replacement Headgear Components
Filter replacement depends on:
- Workplace contaminants
- Exposure levels
- Duration of use
- Filter loading
Users should replace filters whenever breathing performance decreases, airflow alarms activate, or according to their site's respiratory protection program and maintenance schedule.
To keep your PAPR performing at its best:
- Inspect before each use.
- Charge the battery after use.
- Clean the headtop and visor according to the user instructions.
- Replace filters and consumables as required.
- Store the unit in a clean, dry environment.
Routine inspections help maximise product life and user safety.
The TRIDENT® HEXHALE® PAPR unit and batteries are backed by a 12-month manufacturer's warranty covering manufacturing defects and workmanship under normal use. Used or contaminated products cannot be returned unless they are faulty under warranty conditions.
Replacement filters, batteries, visors, chargers, accessories and spare parts are available directly through Industree or authorised distributors, ensuring your PAPR system remains fully operational.